DX-120 Installation and Maintenance Manual INSTALLING THE DX-120
Adding an MDM (continued)
INSTALLING THE MDM
1) Be sure that the entire system is turned off.
2) Remove the KSU cover (four screws at each corner).
3) Install a static discharge wrist strap on your bare wrist, and adjust it for a snug fit.
CAUTION
Be sure that the strap is touching bare skin and is not isolated by clothing.
4) Connect the wrist strap cord between the wrist strap and an AC or earth ground.
5) Connect a static discharge wrist strap to a suitable earth ground.
CAUTION
Circuit boards are susceptible to damage caused by electrostatic
discharge. You must keep this in mind as you handle the circuit boards.
For additional information, see Vertical publication IMI01-005, Handling of
Electrostatically Sensitive Components.
6) Locate the CPM at the right-hand side of KSU1, above the 408M (and COM4 if installed).
7) Position the MDM over the CPM-MDM connectors as shown below.
HINT
Press firmly (but not forcefully) on the MDM to secure a good connection into the
CPM-MDM connectors.
8) Replace the KSU cover and secure with cover screws.
9) Restore KSU power.