Specifications 2-4
Chapter 2: System Overview
MBX IP Hardware & Installation Guide
Specifications
General Parameters
DIMENSION AND WEIGHT
ENVIRONMENT
SYSTEM ELECTRICAL
ITEM HEIGHT (in.) WIDTH (in.) DEPTH (in.) WEIGHT(lbs)
BKSU 6.7006 17.3224 12.8107 13.6686
EKSU 6.7006 17.3224 12.8107 13.7788
Digital Keyset .41537 7.9919 4.8817 1.9841
Digital DSS/DLS Console 6.0628 6.8895 4.3699 .8815
Digital ICM/Door Box 1.2598 5.1967 3.8975 1.1023
ITEM DEGREES ( °C) DEGREES ( °F)
Operation Temperature 0-40 32-104
Optimum Operation Temperature 20-26 68-78
Storage Temperature 10-70 32-158
Relative Humidity 0-80% non-condensing
ITEM SPECIFICATION (PSU)
1. Power Supply -
- AC Voltage Input 100 - 240 Volt AC @47-63Hz
- AC Power 350W
- AC Input Fuse 6.3A @ 250Volt AC
- DC Output Voltage + 5, + 30Volt DC
- Efficiency Above 80%
2. Battery Backup -
- PSU Input Voltage 24Volt DC
- PSU Battery Fuse 15.0A @250Volt AC
- Charging Current Max. 1A
Release 1.7