Pre-Installation 3-2
Chapter 3: KSU Installation
MBX IP Hardware & Installation Guide
Wiring Precautions
Be sure to follow these precautions when wiring:
Do not wire the telephone cable in parallel with an AC power source, such as a computer,
fax machine, etc. If the cables are run near those wires, shield the cables with metal tubing
or use shielded cables and ground the shields.
If the cables are run on the floor, use protectors to prevent the wires from being stepped
on. Avoid wiring under carpets.
Do not use the same power supply outlet for computers, fax machine, and other office
equipment to avoid induction noise interruption when using the MBX IP.
The power and battery switches must be OFF during wiring. After wiring is completed, the
power switch may be turned ON.
Incorrect wiring may cause the MBX IP System to operate improperly.
If an extension does not operate properly, disconnect the telephone from the extension
line and then re-connect, or turn the System power OFF and then ON again.
Use twisted pair cable for connecting CO lines.
Release 1.7
April 2012