MBX IP Hardware & Installation Guide
Frame Ground Connection
It is very important that the frame of the MBX IP System is grounded:
1. Turn the grounding screw counter clockwise to loosen, as shown in the figure below.
2. Insert the grounding wire and tighten the screw.
3. Then connect the grounding wire to an appropriate ground source (refer to Caution).
C
AUTION:
The equipment should be connected to a socket-outlet with a protective ground
connection.
For ground wire, green-and-yellow insulation is required and the cross-sectional
area of the conductor must be more than UL 1015 AWG#18 (1.0mm). It is
recommended that the ground wire is shorter than 1m (3.28ft).
Proper grounding is very important to protect the MBX IP system from external
noise or to reduce the risk of electrocution in the event of lightning strike.
Be sure to comply with applicable local regulations.