Expansion KSU Installation 3-16
Chapter 3: KSU Installation
MBX IP Hardware & Installation Guide
Expansion KSU Installation
Using Expansion Cable
1. Turn the screw counter-clockwise to loosen and then remove the Dummy Cap. Also, the
Dummy Cap of the 2nd KSU should be opened in the same manner at three KSU system.
2. To operate the System, each KSU should be connected using the Expansion cable as
shown below. Make sure that the Expansion cable is connected correctly, and not facing
the wrong direction.
3. Connect Fasteners with screws to affix the MBX IP system.
Expansion KSU Installation
NOTE: Be careful not to bend the pins of connectors.
- When the Expansion Cable is inserted in an uneven manner, the connector pins
(male) on MB/MBE may be bent. So, be careful when making connections.
- Before connection of Expansion Cable, remove Dummy Caps and Dummy Plates.