For CO Transit-Out, any code will be available using NET Routing Table (PGM 324). If
there is a conflict between NET Routing Table and System Numbering Plan, the System
Numbering Plan will have the highest priority.
If the CO Transit-Out code is programmed in the Network Numbering Plan Table, then
the type value of this entry must be set to PSTN (PGM 324).
If the Networked System isn't connected to the Master System directly, the CO
Transit-Out code can be transmitted through the other networked Systems transparently
by setting the PGM 324.
At the Master System, the PSTN CO lines must be set (PGM 322).
Admin Programming
Networking CO Line Type (PGM 322 - FLEX 2)
Network Routing Table - Numbering Plan (PGM 324)
Do-Not-Disturb (DND)
Net Calls to a Station can be rejected using the DND mode; the Calling Station will hear a busy
tone.
Operation
To activate DND mode:
1. Press the [DND] button at the Station.
2. When a call is received at the Station, the Caller will hear a busy tone; the Station in DND
mode will not receive any notification of the call.
Condition
When a Station is in DND mode, the [NET DSS] of the DND Station will flash if the BLF
(Busy Lamp Field) manager is activated.
Admin Programming
DND Attribute (PGM 111)