- 293 -
DX-120 Programming Manual BASIC CALL HANDLING PROGRAMMING TASKS
Setting Hold Abandon Time Interval (continued)
SETTING HOLD ABANDON TIME INTERVAL VIA THE DET
NOTE
• chg, bksp, save, one, always, del, and ack are interactive LCD button operations.
Use the three buttons below the LCD display to activate the associated operation.
• You can press Hold at any time to return to the previous level or press the volume
buttons to return to the main DB selection screen.
1) Enter Database Administration (see page 26) using the feature code Feature # * to display the password
prompt.
2) Enter the DB Admin password (see page 27).
3) Press show to display the DB Item Select screen.
4) Enter 03-43.
5) Press save to display the Hold Abandon Time field.
6) Press chg until you see the number of milliseconds you want the system to wait when detecting a drop in
loop current before abandoning a call on hold.
• Valid options are between 50 and 1000 milliseconds, in intervals of 50 (50, 100, 150, 200, etc.).
• The default is 600 milliseconds.
7) Press the Hold button to return to the previous menu level.
OR
Press the volume UP button to return to the DB Item Selection screen.
OR
Exit programming (see “Exiting Database Administration” on page 27.