External Device Control 1-95
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
OPERATION / SETUP
To use the Door Open feature:
Enter the Door Open code.
-or-
Press the programmed {DOOR OPEN} button.
To assign a {DOOR OPEN} flex button:
1. Press [TRANS/PGM], then press the flex button to be assigned.
2. Enter one of the following sequences:
#*1 = 1st Door Open
#*2 = 2nd Door Open
#*3 = 3rd Door Open
#*4 = 4th Door Open
3. Press [HOLD/SAVE] to store the setting.
Doorboxes
A convenient intercom Doorbox can be connected to the system. The intercom Doorbox can be
used to receive page announcements and intercom calls. The Doorbox can also signal
assigned stations in the system. Any combination of digital phones or Doorboxes can be
arranged in the system.
CONDITIONS
The Doorbox cannot:
- participate in a conference call.
- receive a CO call.
A Doorbox can be a member of a page zone group.
To receive a Doorbox call on an SLT, the Doorbox Signaling value must be set to ON (see
ADMIN PROGRAMMING for this feature).
SLTs and cordless phones can only receive one call from the Doorbox.
Also see "ICM Box Music" on page 1-17.