Other Programming Tables 1-238
Chapter 1: Basic System Features
SBX IP Programming & Operations Guide
DCOB Attribute (PGM 186-187)
DCOB Attribute 1 (PGM 186)
DCO CO Type -- N/A
see PGM 187 (Flex4)
PGM 186 + FLEX 1 + Value +
[HOLD/SAVE]
VALUES --
(reserved)
Metering Type -- use call metering signal. PGM 186 + FLEX 2 + 0 Value
+ [HOLD/SAVE]
VALUES --
0 = Off
1 = On
R2 OUT Manage Timer -- in R2-DCO signaling,
maximum wait time for forward signal from PX.
PGM 186 + FLEX 3 + 14 secs
(2 digits) + [HOLD/SAVE]
VALUES --
Range = 01-50
R2 IN Manage Timer -- in R2 signaling, maximum
time for waiting for forward signal from PX (1 sec).
PGM 186 + FLEX 4 + 14 secs
(2 digits) + [HOLD/SAVE]
VALUES --
Range = 01-50
R2 Disappear Timer -- based on compelled
signaling, it is a waiting timer until the R2 signal is
stopped.
PGM 186 + FLEX 5 + 14 secs
(2 digits) + [HOLD/SAVE]
VALUES --
Range = 01-50
R2 Pulse Timer -- in R2 signaling, time duration to
send pulse typed R2 signal (20 msec).
PGM 186 + FLEX 6 + 07 Time
(2 digits) + [HOLD/SAVE]
VALUES --
Range = 01-30
(20 msec base)
R2 Ready Timer -- in the case of an incoming call,
after R2 Ready Timer expires, the seize ack signal
is sent if a seize signal is received.
PGM 186 + FLEX 7 + 007 Time
(3 digits) + [HOLD/SAVE]
VALUES --
Range = 000-500
(20 msec base)
Dial Tone Delay Timer -- not used PGM 186 + FLEX 8 + 20 Time
(2 digits) + [HOLD/SAVE]
VALUES --
Range = 01-30
Line Status -- based on the R2 specifications, this
value is sent if a called destination is idle.
PGM 186 + FLEX 9 + 6 Value
(1 digit)+ [HOLD/SAVE]
VALUES --
Range = 1-9
Calling Category -- based on the R2
specifications, this value is sent if a PX asks the
calling category.
PGM 186 + FLEX 10 + 1 Value
(1 digit) + [HOLD/SAVE]
VALUES --
Range = 1-9
ANI Request -- request the CID to the called party. PGM 186 + FLEX 11 + 0 Value
+ [HOLD/SAVE]
VALUES --
0 = Off
1 = On
CLI Digit Number -- not used PGM 186 + FLEX 12 + 04
Value (2 digits) +
[HOLD/SAVE]
VALUES --
Range = 01-10