System Timers 3 (PGM 182)
LCO Connect Timer (CIS only) -- N/A
To check LCO status after LCO is connected, the system
assigns CPT periodically with this timer. To activate, CO -
CO XFER CPT detect should be set to ON (PGM 160 -
FLEX 16).
PGM 181 + FLEX 18 + 00
Seconds (2 digits) +
[HOLD/SAVE]
VALUES --
Range = 00-30
LCO CPT Detect Timer -- N/A
To check LCO status after LCO is connected, the system
assigns CPT periodically with this timer. To activate, CO -
CO XFER CPT detect should be set to ON (PGM 160 -
FLEX 16).
PGM 181 + FLEX 19 + 05
Seconds (2 digits) +
[HOLD/SAVE]
VALUES --
Range = 00-20
Wink Timer (future feature) -- designates the amount
of time needed to acknowledge a signal on a DID line.
PGM 182 + FLEX 9 + 010
Value (10 msec, 3 digits)
+ [HOLD/SAVE]
VALUES --
Range = 010-200
Enblock Digit Timer -- designates the amount of time
allowed before enblock dialing is activated when the
user is making an enblock dialing mode call.
PGM 182 + FLEX 10 + 05
Value (10 sec, 2 digits) +
[HOLD/SAVE]
VALUES --
Range = 01-20
CCR Time Out Timer -- N/A
> CCR Time Out can be controlled via the InterDigit
Timer in PGM 181 Button 8. Note: This timer must be
longer than the CCR InterDigit Timer. Changing the
InterDigit Timer will impact other functions.
PGM 182 + FLEX 11 +
015 Seconds (2 digits) +
[HOLD/SAVE]
VALUES --
Range = 000-300
DID Inter-digit Timer -- designates the amount of time
before call routing of DID type 2 is executed.
PGM 182 + FLEX 12 + 05
Seconds (2 digits) +
[HOLD/SAVE]
VALUES --
Range = 01-20